CONTEG COLD AISLE COOLING Racks are aligned front to front and cold air is delivered using the raised floor as a cold air handling space (plenum).
CONTEG CONTAINMENT COOLING The contained aisle solution can be deployed where higher density loads are found to ensure that all available cooling air is directed to the cabinets
DATA CENTER COOLING PLENUM FEED WITH ROOM RETURN
The CONTEG Plenum Feed with Room Return
solution optimises the use of cooled air by directing the cooled
air directly from the raised floor to the equipment within the
rack. A deflector located in the bottom of the
rack directs the cold air to the front of the rack to be drawn
through the equipment mounted inside.
ROOM FEED WITH PLENUM RETURN CONTEG's Hot Plenum Return Kit addresses this requirement by using a vertical "chimney" at the top rear of the rack directly connected to a hot plenum at ceiling height. A turning vane located at the bottom rear of the rack helps to optimise the flow of hot exhaust into the "flue", while the large surface area of the chimney ensures that large volumes of air can be passed at relatively low velocities.
CONTEG SIDE MOUNT CLOSED LOOP Side Mount Closed Loop Architecture represents the ultimate in flexibility. High Density cooling units are combined with RDF racks to provide a "closed module" with a common cold zone at the front of the racks and a common hot zone at the rear of the racks.
LIEBERT CHALLENGER 3000 Liebert Challenger 3000 is available in 10.5- and 17.5-kW (3 and 5 tons) capacities, 60Hz and 50Hz models. Air-cooled, water-cooled, glycol-cooled, GLYCOOL™ and chilled water configurations. Upflow and downflow models available.
|
||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||